Bai, Xueding et al. published their research in Journal of Medical Virology in 2020 | CAS: 76-54-0

2′,7′-Dichloro-3′,6′-dihydroxy-3H-spiro[isobenzofuran-1,9′-xanthen]-3-one (cas: 76-54-0) belongs to benzofurans derivatives. Benzofuran derivatives are one of the most important oxygen-containing heterocycles. Benzofurans are stable towards alkali and readily polymerize on treatment with sulfuric acid, due to which they are useful for the preparation of low cost chemically relatively inert resins.Safety of 2′,7′-Dichloro-3′,6′-dihydroxy-3H-spiro[isobenzofuran-1,9′-xanthen]-3-one

Field applicable detection of hepatitis B virus using internal controlled duplex recombinase-aided amplification assay and lateral flow dipstick assay was written by Bai, Xueding;Ma, Xuejun;Li, Minghui;Li, Xinna;Fan, Guohao;Zhang, Ruiqing;Wang, Ruihuan;Duan, Qingxia;Shen, Xinxin;Xie, Yao;Rong, Xiuge. And the article was included in Journal of Medical Virology in 2020.Safety of 2′,7′-Dichloro-3′,6′-dihydroxy-3H-spiro[isobenzofuran-1,9′-xanthen]-3-one This article mentions the following:

Hepatitis B virus (HBV) is a widespread blood-borne pathogen associated with the complication of liver cirrhosis and hepatocellular carcinoma, particularly in south-east Asian and African countries where HBV is highly endemic and the budget and resources are limited. Therefore, simple, rapid, and portable field detection methods are crucial to efficiently control HBV infection. In this study, using heat-treated DNA, we developed two-field applicable detection assays for HBV based on recombinase-aided amplification (RAA). One was an internal controlled duplex RAA assay using a portable real-time fluorescence detection device, another was an instrument-free visual observation assay using lateral flow dipsticks. The entire exptl. time was greatly shortened to less than 40 min at 39.0°C. The sensitivities, specificities, and clin. performance of both assays were evaluated. Compared with quant. polymerase chain reaction assay as a reference, our results demonstrated that the two RAA-based assay obtained 97.18% and 95.77% of sensitivity, resp., and the specificity was 100%, by testing a total of 157 serum samples with HBsAg pos. We conclude that the advantages of rapidity, simplicity, portability, and visualization of proposed two assays make them great potentials in point-of-care testing of HBV infection by untrained people in resource-limited situations. In the experiment, the researchers used many compounds, for example, 2′,7′-Dichloro-3′,6′-dihydroxy-3H-spiro[isobenzofuran-1,9′-xanthen]-3-one (cas: 76-54-0Safety of 2′,7′-Dichloro-3′,6′-dihydroxy-3H-spiro[isobenzofuran-1,9′-xanthen]-3-one).

2′,7′-Dichloro-3′,6′-dihydroxy-3H-spiro[isobenzofuran-1,9′-xanthen]-3-one (cas: 76-54-0) belongs to benzofurans derivatives. Benzofuran derivatives are one of the most important oxygen-containing heterocycles. Benzofurans are stable towards alkali and readily polymerize on treatment with sulfuric acid, due to which they are useful for the preparation of low cost chemically relatively inert resins.Safety of 2′,7′-Dichloro-3′,6′-dihydroxy-3H-spiro[isobenzofuran-1,9′-xanthen]-3-one

Referemce:
Benzofuran – Wikipedia,
Benzofuran | C8H6O – PubChem