Fernandez-Ramos, M. D.’s team published research in Talanta in 208 | CAS: 596-01-0

Talanta published new progress about 596-01-0. 596-01-0 belongs to benzofurans, auxiliary class Benzofuran,Naphthalene,Alcohol,Ester, name is 3,3-Bis(4-hydroxynaphthalen-1-yl)isobenzofuran-1(3H)-one, and the molecular formula is C28H18O4, Recommanded Product: 3,3-Bis(4-hydroxynaphthalen-1-yl)isobenzofuran-1(3H)-one.

Fernandez-Ramos, M. D. published the artcileOptical portable instrument for the determination of CO2 in indoor environments, Recommanded Product: 3,3-Bis(4-hydroxynaphthalen-1-yl)isobenzofuran-1(3H)-one, the publication is Talanta (2020), 120387, database is CAplus and MEDLINE.

A portable device based on a colorimetric sensor to determine the atm. level of CO2 gas is presented in this work. The system is based on a low-cost, low-power System on a Chip (SoC) microcontroller with integrated Wi-Fi. A user-friendly application was developed to monitor and log the CO2 measurements when the system is connected to a Wi-Fi network. The sensing membrane is directly deposited on the surface of the color detector, thus reducing the complexity of the system. This sensing membrane is formed by a pH indicator α-naphtholphthalein, tetramethylammonium hydroxide pentahydrate, 1-ethyl-3-methylimidazolium tetrafluoroborate, Tween 20 and hydroxypropyl methylcellulose as the hydrophilic polymer. The system has been fully characterized, obtaining response and recovery times of 1.3 and 2.5 s, resp., a limit of detection of 51 ppm, and an average resolution of 6.3 ppm. This portable device was applied for the in-situ determination of CO2 gas in the atm. inside classrooms in several secondary schools. The measurements were taken during complete workdays and the results were statistically compared with the same measurements taken using a com. available non-dispersive infra-red (NDIR) device. No significant statistical differences were found between the results obtained using both devices. A complete statistical treatment of the measurements made with the proposed portable device was carried out. The obtained results show that the concentration of CO2 gas in some schools was higher than the desired concentration, with regard to influencing the student’s health, safety, productivity and comfort. This demonstrates the need to control this parameter to ensure appropriate indoor environmental quality (IEQ).

Talanta published new progress about 596-01-0. 596-01-0 belongs to benzofurans, auxiliary class Benzofuran,Naphthalene,Alcohol,Ester, name is 3,3-Bis(4-hydroxynaphthalen-1-yl)isobenzofuran-1(3H)-one, and the molecular formula is C28H18O4, Recommanded Product: 3,3-Bis(4-hydroxynaphthalen-1-yl)isobenzofuran-1(3H)-one.

Referemce:
https://en.wikipedia.org/wiki/Benzofuran,
Benzofuran | C8H6O – PubChem