Konda, Satyanand et al. published their research in Separation Science plus in 2022 | CAS: 80621-81-4

(2S,16Z,18E,20S,21S,22R,23R,24R,25S,26R,27S,28E)-25-(Acetyloxy)-5,6,21,23-tetrahydroxy-27-methoxy-2,4,11,16,20,22,24,26-octamethyl-2,7-(epoxypentadeca[1,11,13]trienimino)benzofuro[4,5-e]pyrido[1,2-a]benzimidazole-1,15(2H)-dione (cas: 80621-81-4) belongs to benzofurans derivatives. Many natural or synthetic compounds containing benzofuran skeletons have been found to possess remarkable activity as agrochemicals and pharmaceuticals. As benzofurans are prone to undergo ring opening of the heterocycle, examples of reduction of this type of aromatics by using dissolving metals are rather scarce.HPLC of Formula: 80621-81-4

Development and evaluation of a multi-class analytical method based on solid-phase extraction combined with liquid chromatography-tandem mass spectrometry for the analysis of pharmaceuticals and personal care products in urban wastewater samples was written by Konda, Satyanand;Asati, Ankita;Williams, Mike;Mudiam, Mohana Krishna Reddy. And the article was included in Separation Science plus in 2022.HPLC of Formula: 80621-81-4 This article mentions the following:

An anal. method has been developed for the quant. evaluation of 64 pharmaceuticals and personal care products in urban wastewater using solid-phase extraction coupled with liquid chromatog.-tandem mass spectrometry. Design of experiments approach was used in the multiparametric optimization of solid-phase extraction method for the anal. of pharmaceuticals and personal care products. The method was found to be linear within the range of 0.01-1 μg/L with coefficient of determination (R2) ranging from 0.990 to 0.999. The limit of detection and limit of quantification were found to be in the range of 0.002-0.028 and 0.007-0.091 μg/L, resp. The accuracy was calculated with respect to percent recovery, and it was found to be in the range of 70.0-129% for all the analytes. The intra- and interday precisions were found to be less than 15% relative standard deviation for all the analytes. The developed anal. method was applied to real samples collected from four different sampling sites of Musi River in Hyderabad to evaluate its performance. The method found a wide application for the anal. of urban wastewater samples. In the experiment, the researchers used many compounds, for example, (2S,16Z,18E,20S,21S,22R,23R,24R,25S,26R,27S,28E)-25-(Acetyloxy)-5,6,21,23-tetrahydroxy-27-methoxy-2,4,11,16,20,22,24,26-octamethyl-2,7-(epoxypentadeca[1,11,13]trienimino)benzofuro[4,5-e]pyrido[1,2-a]benzimidazole-1,15(2H)-dione (cas: 80621-81-4HPLC of Formula: 80621-81-4).

(2S,16Z,18E,20S,21S,22R,23R,24R,25S,26R,27S,28E)-25-(Acetyloxy)-5,6,21,23-tetrahydroxy-27-methoxy-2,4,11,16,20,22,24,26-octamethyl-2,7-(epoxypentadeca[1,11,13]trienimino)benzofuro[4,5-e]pyrido[1,2-a]benzimidazole-1,15(2H)-dione (cas: 80621-81-4) belongs to benzofurans derivatives. Many natural or synthetic compounds containing benzofuran skeletons have been found to possess remarkable activity as agrochemicals and pharmaceuticals. As benzofurans are prone to undergo ring opening of the heterocycle, examples of reduction of this type of aromatics by using dissolving metals are rather scarce.HPLC of Formula: 80621-81-4

Referemce:
Benzofuran – Wikipedia,
Benzofuran | C8H6O – PubChem